Fan Motors for HVAC & Ventilation – Hazardous and Safe Areas
Motors for axial, duct and centrifugal fans: RAEL flameproof motors where the air may be explosive, and Lafert IE3 to IE5 motors for HVAC, condensers and ventilation in safe areas. For fan manufacturers, contractors and industrial projects across the Gulf.
Send your project RFQWhatsApp +971 50 269 7191
First question: is the air around the fan hazardous?

Hazardous area – RAEL Tube
Flameproof Ex db IIC motor for axial and duct fans, 36–38% lower profile than the RAEL RL, terminal box at the back. Frame 56 – 71.
RAEL Tube →
Hazardous area – RAEL RL
For larger fans and centrifugal blowers up to frame 160, including two-speed quadratic-torque motors for fans.
RAEL RL →
Safe area – Lafert pad mounting
Air-over motors on four pads for direct-drive axial fans, IE3, IE4 and IE5, frame 80 – 160.
Pad mounting motors →Which motor for which fan
| Application | Area | Recommended motor |
|---|---|---|
| Battery room exhaust (hydrogen) | Zone 1 / 2, IIC | RAEL Tube or RL Ex db IIC |
| Analyser shelters, pump and compressor houses | Zone 1 / 2 | RAEL Tube / RL |
| Paint and solvent rooms, chemical stores | Zone 1 / 2 | RAEL RL Ex db, Ex tb where dust is present |
| Duct and wall fans in Zone 2 | Zone 2 | RAEL MIA1 Ex ec or Tube |
| Condenser, dry cooler and cooling tower fans | Safe area | Lafert pad mounting (air-over) |
| Air handling units and centrifugal fans | Safe area | Lafert IE3 / IE4 |
| Car park and general ventilation, two speeds | Safe area | Lafert AMV two-speed for fans |
| Fans that run all year (energy saving) | Safe area | Lafert HPS IE5 on inverter |
Gulf conditions that change the motor choice
- Heat: roof and condenser fans see air well above 40 °C – the rating must be confirmed for your air temperature.
- Air-over motors (pad mounting) have no own fan and must sit in the fan’s air stream; never use them in a hazardous area.
- Sand and humidity: IP66, drain holes and corrosion protection for coastal and outdoor fans.
- Saudi Arabia: 60 Hz and IE3 from 0.75 kW (SASO 2893) for three-phase motors.
- Hydrogen in battery rooms requires gas group IIC – a IIB motor is not enough.
For fan manufacturers
If you build fans – axial, duct or ATEX fans – we support you as a motor supplier, not just for single motors:
- Motor selection per fan size and duty point
- Dimension drawings for your fan design
- Sample motors for prototypes and type testing
- Annual pricing for repeat orders
- Explosion-proof (RAEL) and safe-area (Lafert) motors from one supplier
- Mounting options: B5, B14, feet or pads
Frequently asked questions
Which motor for a battery room exhaust fan?
Battery rooms can release hydrogen, so the motor must be explosion-proof for gas group IIC – for example a RAEL Tube or RL Ex db IIC motor, suitable for Zone 1 and 2.
Can I use an air-over pad mounting motor in a hazardous area?
No. Lafert pad mounting motors are for safe areas only. For hazardous areas use a certified explosion-proof motor such as RAEL Tube.
What is the advantage of the RAEL Tube for axial fans?
Tube is a flameproof Ex db IIC motor with a 36–38% lower profile and the terminal box at the rear, so it fits inside a duct and disturbs the airflow less than a standard RL motor.
Which motor for a two-speed ventilation fan?
For safe areas, the Lafert AMV two-speed series is matched to fan torque. For hazardous areas, the RAEL RL two-speed quadratic-torque version.
Do fan motors in Saudi Arabia need IE3?
Three-phase motors from 0.75 kW need IE3 under SASO 2893. Lafert IE3, IE4 and IE5 pad mounting motors meet this.
Do you work with fan manufacturers on repeat orders?
Yes. Send your fan range and expected annual quantities and we propose motors, drawings and annual pricing.
Fan project or fan production?
Send the fan type, kW, speed, area classification and quantities – we reply with a motor selection and quotation.