IEC Low Voltage Electric Motors – IE2, IE3 and IE4

Three-phase, single-phase and brake motors to IEC 60034, 0.06 – 200 kW, frame 56 – 315, for 50 Hz and 60 Hz networks. Choose the efficiency class your country requires and the version for your site – KJ Export supplies the Gulf from Dubai.

Request a quoteWhatsApp +971 50 269 7191
IE2 · IE3 · IE4IEC 6003450 / 60 HzIP55
IEC low voltage three-phase motor
0.06 – 200 kW2 to 8 poles
Frame 56 – 315aluminium and cast iron
IE1 – IE4to IEC 60034-30-1
SASO 2893IE3 for Saudi Arabia

Our low voltage motor range

IE3
Lafert IE3 motor

IE3 premium efficiency

Lafert AMPE (400 V 50 Hz) and AMPH (460 V 60 Hz, NEMA Premium).

0.12 – 55 kWSaudi ready
IE3 motors →
IE4
Lafert IE4 motor

IE4 super premium

Lafert AMQE for continuous duty – lowest losses in standard IEC frames.

0.75 – 200 kWFrame 80 – 315
IE4 motors →
IE2
Lafert IE2 motor

IE2 and two-speed

Lafert AMHE / AMEE and AM / AMV two-speed motors.

0.12 – 22 kW50 / 60 Hz
IE2 motors →
230 V
Single-phase motor

Single-phase motors

Capacitor motors with standard or high starting torque, IE2 and dual-voltage.

0.09 – 2.2 kWFrame 56 – 100
Single-phase →
Brake
Brake motor

Brake motors

Fail-safe DC and AC brakes for hoists, conveyors and machinery.

0.12 – 22 kW1.8 – 250 Nm
Brake motors →
Ex
Explosion-proof motor

Explosion-proof motors

For Zone 1 / 2 hazardous areas: flameproof Ex db, Ex eb and Ex ec motors by RAEL.

ATEX · IECEx0.035 – 18.5 kW
Explosion-proof →

Building axial fans? See the Lafert pad mounting motors for axial fans (IE3, IE4, IE5) – and for hazardous areas the flameproof RAEL Tube.

How to choose a low voltage motor

1. Efficiency class (IE code)

IEC 60034-30-1 defines four efficiency classes. The higher the class, the lower the losses – nominal efficiency at 50 Hz, 4 pole:

ClassName1.1 kW7.5 kW55 kW
IE1Standard efficiency75.0%86.0%92.1%
IE2High efficiency81.4%88.7%93.5%
IE3Premium efficiency84.1%90.4%94.6%
IE4Super premium efficiency87.2%92.6%95.7%

2. What your country requires

The IE class sets the levels; each country decides the minimum (MEPS). For Gulf projects the client specification often adds its own requirement – check it before you order.

MarketRegulationMinimum level (three-phase)
Saudi ArabiaSASO 2893 (since 01.01.2017)IE3 for 0.75 – 375 kW, 2 – 8 poles, 380 / 400 V 60 Hz
European Union, UK, Switzerland, TurkeyEU 2019/1781 + 2021/341 (since 01.07.2023)IE2 0.12 – 0.75 kW · IE3 0.75 – 1000 kW · IE4 75 – 200 kW (2 – 6 poles)
USA and CanadaDOE 10 CFR 431 / CSA C390-10NEMA Premium (IE3), 1 – 500 HP, 60 Hz
Other Gulf countriesProject / client specificationWe supply IE2, IE3 or IE4 as specified

3. Voltage and frequency

Standard three-phase motors are rated 230/400 V Δ/Y (up to about 3 kW) or 400/690 V Δ/Y (from 4 kW), 50 Hz, and single-speed motors are also marked with the 60 Hz voltage range. A 50 Hz motor on 60 Hz with proportionally higher voltage runs 1.2× faster and gives 1.15× the output. For Saudi Arabia (380 / 400 V 60 Hz) we select motors with the correct 60 Hz rating.

4. Mounting arrangement

CodeMountingTypical use
IM B3Foot mounted, horizontalPumps on baseplates, belt drives, general machinery
IM B5Large flange (type A, through holes)Gearboxes, pumps with lantern
IM B14Small face flange (type C, tapped holes)Compact machines, small pumps and fans
IM B35 / B34Feet + flangeHeavier flange-mounted drives
IM V1 / V5 / V6Vertical, shaft down or upVertical pumps, mixers, fans

5. Hot sites: derating above 40 °C

Rated outputs are for 40 °C ambient and up to 1000 m altitude. With class B temperature rise the motor must be derated:

Ambient temperature45 °C50 °C55 °C60 °C
Output (class B rise)≈ 95%≈ 90%≈ 85%≈ 80%

A winding utilised to class F (105 K) needs no derating up to 55 °C. For outdoor and coastal Gulf sites also consider a higher degree of protection, special K1 paint, anti-condensation heaters and a protective cowl for vertical mounting.

6. Duty and starting

Permissible starts per hour (load torque rising with the square of the speed):

Shaft height2 poles4 poles≥ 6 poles
56 – 71100250350
80 – 10060140160
112 – 132306080
160 – 180153050
200 – 22581530
250 – 3154812

For frequent starts and stops, holding loads or emergency stopping choose a brake motor; for variable speed, frame 90 and up run on frequency inverters in standard design.

Frequently asked questions

Which efficiency class do I need in Saudi Arabia?

IE3 for three-phase motors from 0.75 to 375 kW, according to SASO 2893. IE4 motors also meet this requirement.

What is the difference between IE2, IE3 and IE4?

They are efficiency classes defined in IEC 60034-30-1: IE2 high, IE3 premium and IE4 super premium efficiency. Each step reduces the motor losses by roughly 15 – 25%.

Can I use a 50 Hz motor on a 60 Hz supply?

Yes, if the voltage is adjusted: with a proportional voltage increase the speed rises by 1.2× and the output by 1.15×. Without the higher voltage the output cannot be increased.

What is the difference between B5 and B14 flanges?

B5 is a large flange with through holes (type A to DIN 42948); B14 is a smaller face flange with tapped holes (type C). The mounting must be stated in the order.

Do motors need derating in the Gulf?

Above 40 °C ambient, yes: about 5% per 5 °C for class B temperature rise, unless the winding is utilised to class F. Tell us your site temperature and we confirm the rating.