Industries · Oil & Gas · Petrochemical · Chemical

Explosion-Proof Motors for Oil & Gas Projects

ATEX and IECEx motors by RAEL for pumps, fans, mixers and hoists in Zone 1 and Zone 2 process areas. We work from your material requisition and datasheets, check every tag against the area classification and supply the documentation your project needs for approval.

Send your project RFQWhatsApp +971 50 269 7191
ATEXIECExEx db · Ex eb · Ex ecIIC · IIBT4 – T6
RAEL explosion-proof motors for oil and gas projects
Zone 1 · 2 · 21 · 22gas and dust hazardous areas
0.035 – 18.5 kWIEC frame 56 – 160
50 / 60 HzGulf voltages, IP66, marine paint
Since 2010RAEL’s exclusive Middle East agent

Where our motors are used in oil & gas plants

Typical selections – the final choice always follows your area classification drawing and project specification.

ApplicationTypical areaRecommended motorNotes
Chemical injection and dosing pumpsZone 1, IIB / IICRAEL RL Ex dbSmall 4-pole ratings, B5 / B14 flange on the pump
Transfer, sump and drain pumpsZone 1 / 2RAEL RL Ex dbIP66 and Ex tb version where dust is present
Lube oil and seal oil pumps on packagesZone 1 / 2RL or MIAEx eb (MIA) is lighter where the client accepts Ex e
Agitators and mixers in tanksZone 1RAEL RL with gearboxTwo-speed and inverter-duty versions available
Analyser shelter, battery room and pump house exhaust fansZone 1 / 2, often IICRAEL Tube Ex db IICLow profile for axial and duct fans; IIC covers hydrogen
Larger fans and centrifugal blowersZone 1 / 2RL two-speed quadratic torqueFrame up to 160
Monorails, hoists and drives that must hold the loadZone 1RAEL BrakExFlameproof brake motor, IIB, IIB+H2 or IIC
Fuel loading, dispensing and vapour recoveryZone 1RAEL ADPEPurpose-built Ex db dispenser motor
General Zone 2 process areasZone 2RAEL MIA1 Ex ecNon-sparking, lighter than Ex d

What we check on every tag

Send the motor datasheets or the MR – we go through each point below and list any deviation before we quote.

Ex protection

Zone and EPL (Gb / Gc), type of protection (Ex db, Ex db eb, Ex eb, Ex ec), gas group IIA / IIB / IIC, temperature class, dust (Ex tb / Ex tc).

Electrical

Voltage and frequency – 50 Hz in the UAE, Qatar, Oman, Kuwait, Bahrain and Iraq; 60 Hz in Saudi Arabia – starting method, inverter duty, thermal protection (PTC / PTO), space heaters.

Site conditions

Ambient temperature (Gulf sites up to +55 / +60 °C), IP55 or IP66, coastal and offshore paint system, altitude.

Mechanical

Mounting (B3, B5, B14, B35, vertical), shaft and flange, cable entries (metric or NPT), terminal box position, bearing and noise requirements.

Documentation for your project

For each tag we prepare the documents your EPC or end user needs for approval:

  • Completed motor datasheet in your format
  • Technical compliance and deviation list
  • ATEX and IECEx certificates of the series
  • EU declaration of conformity
  • Dimension (GA) drawings
  • Nameplate data and Ex marking per tag
  • Installation and maintenance instructions
  • Recommended spare parts list
  • Factory test reports on request
RAEL seriesCertificateScope
RL IICTÜV IT 13 ATEX 039 XEx db / Ex db eb IIC T6…T4 Gb · Ex tb IIIC Db
RL IIBTÜV IT 13 ATEX 038 XEx db / Ex db eb IIB T6…T4 Gb · Ex tb IIIC Db
RL three- and single-phaseIECEx CCVE 15.0003XFrame 56 – 160
MIA / MIA1TÜV IT 12 ATEX 068 X / 069 XEx eb IIC Gb / Ex ec IIC Gc · Ex tb / Ex tc IIIC
BrakExCESI 20 ATEX 040 X · IECEx CES 24.0001XEx db / Ex db eb IIB, IIB+H2, IIC

How a project enquiry works

StepWhat happens
1. Send the MR / datasheetsBy email, with project name, end user, quantities per tag and required delivery
2. Technical reviewWe check each tag and send back questions and a deviation list, if any
3. QuotationPrice per tag, delivery time and documentation list
4. Documents for approvalDatasheets, drawings and certificates for the EPC / end-user review
5. SupplyManufacturing at RAEL in Italy and shipment consolidated by tag

Need a motor for safe areas in the same project?

Pumps, fans and utilities outside the hazardous area need standard IEC motors – in Saudi Arabia IE3 from 0.75 kW (SASO 2893). See low voltage motors, IE3 and brake motors, so one supplier can cover both lists.

Frequently asked questions

Ex d or Ex e motor for a pump in Zone 1?

Both are allowed in Zone 1. Ex db (flameproof, RAEL RL) is the most widely specified. Ex eb (increased safety, RAEL MIA) is lighter, but needs protection within the time tE and must be accepted by the project specification.

Do I need IIC or is IIB enough?

IIB covers most hydrocarbons such as propane and ethylene. IIC is required for hydrogen, acetylene and carbon disulphide – common in battery rooms and some refinery units. A IIC motor can always be used where IIB is required.

Can you fill in our project datasheets?

Yes. Send the datasheets or the MR; we complete them per tag and list any deviation from the specification before quoting.

Do RAEL motors have IECEx as well as ATEX?

Yes. The RL series carries ATEX and IECEx certificates, and BrakEx is also IECEx certified. Certificate numbers are listed above.

Are 60 Hz motors available for Saudi projects?

Yes. RAEL supplies 60 Hz windings and special voltages for Saudi and other 60 Hz networks.

What do you need to quote quickly?

The datasheet or, at minimum: kW, poles or speed, voltage and frequency, area classification (zone, gas group, temperature class), mounting, IP and quantity per tag.

Send your project RFQ

Attach the MR or motor datasheets with the project name and required delivery – we reply with a technical review and quotation.