Lafert IE3 Motors – AMPE and AMPH Series
Lafert IE3 premium efficiency three-phase motors: AMPE for 400 V 50 Hz and AMPH NEMA Premium for 460 V 60 Hz. 0.12 – 55 kW, IEC frame 56 – 280, aluminium and cast iron. Supplied by KJ Export to the UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain and Iraq.
Request a quoteWhatsApp +971 50 269 7191
AMPE or AMPH?
| AMPE | AMPH | |
|---|---|---|
| Efficiency | IE3 to IEC 60034-30-1 | IE3 and NEMA Premium (EISA), verified by UL |
| Rated supply | 400 V 50 Hz | 460 V 60 Hz |
| Range | 0.12 – 55 kW, frame 56 – 280 | 0.75 – 22 kW, frame 80 – 160 |
| Typical use | IEC projects, 50 Hz networks, export | 60 Hz machines, US-spec equipment |
Need the next efficiency level? See Lafert IE4 (AMQE). For motors below 0.75 kW and non-regulated markets see IE2. Not sure which class your country requires? Read the low voltage motor selection guide.
AMPE electrical data – 400 V 50 Hz
Models marked * are higher-output (progressive) motors in the smaller frame. Full data incl. cos φ, torque ratios and inertia on request.
2 pole – 3000 rpm (33 models)
| Type | kW | rpm | In @400 V (A) | IE3 η 100% | Weight (kg) |
|---|---|---|---|---|---|
| AMPE 56Z BA 2 | 0.12 | 2650 | 0.45 | 60.8% | 3.4 |
| AMPE 56Z CA 2* | 0.18 | 2650 | 0.60 | 65.9% | 3.5 |
| AMPE 63Z AA 2 | 0.18 | 2735 | 0.55 | 65.9% | 3.6 |
| AMPE 63Z BA 2 | 0.25 | 2810 | 0.86 | 69.7% | 4.1 |
| AMPE 63Z CA 2* | 0.37 | 2720 | 1.05 | 73.8% | 4.4 |
| AMPE 71Z XA 2 | 0.37 | 2810 | 0.95 | 73.8% | 5.8 |
| AMPE 71Z YA 2 | 0.55 | 2850 | 1.40 | 77.8% | 6.2 |
| AMPE 71Z AA 2* | 0.75 | 2880 | 1.9 | 80.7% | 8.2 |
| AMPE 80Z AA 2 | 0.75 | 2910 | 1.7 | 82.0% | 9.5 |
| AMPE 80Z BA 2 | 1.1 | 2870 | 2.4 | 82.7% | 11.1 |
| AMPE 80Z CA 2* | 1.5 | 2810 | 3.6 | 84.2% | 13.5 |
| AMPE 90S AA 2 | 1.5 | 2875 | 3.0 | 84.2% | 14.0 |
| AMPE 90L BA 2 | 2.2 | 2880 | 4.6 | 86.5% | 16.0 |
| AMPE 90L DA 2* | 3 | 2865 | 6.3 | 87.1% | 18.0 |
| AMPE 100L AA 2 | 3 | 2900 | 5.6 | 87.1% | 22.8 |
| AMPE 100L BA 2* | 4 | 2920 | 8.2 | 88.1% | 26.5 |
| AMPE 112M AA 2 | 4 | 2910 | 7.0 | 88.1% | 27.4 |
| AMPE 112M BA 2* | 5.5 | 2935 | 10.2 | 89.2% | 33.6 |
| AMPE 112M CA 2* | 7.5 | 2930 | 14.4 | 90.1% | 36.0 |
| AMPE 132S ZA 2 | 5.5 | 2920 | 10.0 | 89.2% | 46.0 |
| AMPE 132S TA 2 | 7.5 | 2910 | 13.1 | 90.1% | 53.0 |
| AMPE 132M ZA 2 | 9.2 | 2930 | 16.5 | 90.7% | 58.0 |
| AMPE 132M RA 2* | 11 | 2935 | 19.9 | 91.2% | 59.0 |
| AMPE 132M TA 2* | 15 | 2915 | 26.8 | 91.9% | 68.0 |
| AMPE 160M YA 2 | 11 | 2950 | 19.7 | 91.2% | 87.8 |
| AMPE 160M ZA 2 | 15 | 2940 | 26.7 | 91.9% | 88.9 |
| AMPE 160L ZA 2 | 18.5 | 2950 | 33.0 | 92.4% | 104 |
| AMPE 160L TA 2* | 22 | 2950 | 39.4 | 92.7% | 104 |
| AMPE 180M ZG 2 | 22 | 2955 | 38.5 | 92.7% | 182 |
| AMPE 200L PG 2 | 30 | 2960 | 52.1 | 93.3% | 246 |
| AMPE 200L RG 2 | 37 | 2960 | 64.0 | 93.7% | 265 |
| AMPE 225M PG 2 | 45 | 2965 | 76.8 | 94.0% | 322 |
| AMPE 250M PG 2 | 55 | 2970 | 93.5 | 94.3% | 413 |
4 pole – 1500 rpm (26 models)
| Type | kW | rpm | In @400 V (A) | IE3 η 100% | Weight (kg) |
|---|---|---|---|---|---|
| AMPE 63Z AA 4 | 0.12 | 1370 | 0.4 | 64.8% | 3.3 |
| AMPE 63Z BA 4 | 0.18 | 1360 | 0.6 | 69.9% | 4.1 |
| AMPE 71Z AA 4 | 0.25 | 1420 | 0.7 | 73.5% | 5.7 |
| AMPE 71Z BA 4 | 0.37 | 1410 | 1.0 | 77.3% | 6.0 |
| AMPE 80Z XA 4 | 0.55 | 1440 | 1.3 | 80.8% | 8.2 |
| AMPE 80Z AA 4 | 0.75 | 1435 | 1.8 | 82.5% | 11.0 |
| AMPE 90S AA 4 | 1.1 | 1440 | 2.5 | 84.1% | 15.8 |
| AMPE 90L BA 4 | 1.5 | 1430 | 3.6 | 85.3% | 16.4 |
| AMPE 90L CA 4 | 1.8 | 1430 | 4.5 | 86.0% | 20.0 |
| AMPE 100L AA 4 | 2.2 | 1455 | 4.8 | 86.7% | 21.5 |
| AMPE 100L BA 4 | 3 | 1460 | 6.0 | 87.7% | 29.0 |
| AMPE 112M BA 4 | 4 | 1450 | 8.2 | 88.6% | 36.0 |
| AMPE 132S AA 4 | 5.5 | 1460 | 10.6 | 89.6% | 49.0 |
| AMPE 132M BA 4 | 7.5 | 1465 | 14.2 | 90.4% | 54.0 |
| AMPE 132M CA 4 | 9.2 | 1460 | 17.3 | 91.0% | 62.0 |
| AMPE 132M DA 4* | 11 | 1470 | 21.8 | 91.4% | 71.0 |
| AMPE 160M AA 4 | 11 | 1475 | 21.0 | 91.4% | 100 |
| AMPE 160L BA 4 | 15 | 1465 | 28.5 | 92.1% | 105 |
| AMPE 160L CA 4* | 18.5 | 1470 | 37.0 | 92.6% | 110 |
| AMPE 160L DA 4* | 22 | 1470 | 41.0 | 93.0% | 115 |
| AMPE 180M ZG 4 | 18.5 | 1470 | 33.5 | 92.6% | 181 |
| AMPE 180L ZG 4 | 22 | 1470 | 39.7 | 93.0% | 209 |
| AMPE 200L RG 4 | 30 | 1475 | 53.8 | 93.6% | 284 |
| AMPE 225S PG 4 | 37 | 1485 | 66.1 | 93.9% | 328 |
| AMPE 225M PG 4 | 45 | 1485 | 80.2 | 94.2% | 363 |
| AMPE 250M PG 4 | 55 | 1485 | 97.6 | 94.6% | 442 |
6 pole – 1000 rpm (23 models)
| Type | kW | rpm | In @400 V (A) | IE3 η 100% | Weight (kg) |
|---|---|---|---|---|---|
| AMPE 71Z AA 6 | 0.18 | 910 | 0.6 | 63.9% | 6.1 |
| AMPE 71Z BA 6 | 0.25 | 900 | 0.9 | 68.6% | 6.6 |
| AMPE 80Z AA 6 | 0.37 | 940 | 1.0 | 73.5% | 8.0 |
| AMPE 90S XA 6 | 0.55 | 940 | 1.5 | 77.2% | 15.0 |
| AMPE 90S AA 6 | 0.75 | 940 | 2.2 | 78.9% | 18.1 |
| AMPE 90L BA 6* | 1.1 | 935 | 3.1 | 81.0% | 19.0 |
| AMPE 100L AA 6 | 1.1 | 960 | 3.0 | 81.0% | 25.0 |
| AMPE 100L BA 6 | 1.5 | 920 | 3.8 | 82.5% | 26.0 |
| AMPE 112M BA 6 | 2.2 | 920 | 5.4 | 84.3% | 34.2 |
| AMPE 132S YA 6 | 3 | 975 | 8.0 | 85.6% | 42.0 |
| AMPE 132M YA 6 | 4 | 975 | 9.6 | 86.8% | 46.0 |
| AMPE 132M TA 6* | 5.5 | 975 | 14.2 | 88.0% | 48.0 |
| AMPE 160M YA 6 | 5.5 | 975 | 11.8 | 88.0% | 84.0 |
| AMPE 160M ZA 6 | 7.5 | 980 | 15.7 | 89.1% | 97.0 |
| AMPE 160L ZA 6 | 9.2 | 970 | 19.9 | 89.8% | 105 |
| AMPE 160L TA 6 | 11 | 970 | 22.9 | 90.3% | 105 |
| AMPE 180L ZG 6 | 15 | 978 | 28.2 | 91.2% | 197 |
| AMPE 200L PG 6 | 18.5 | 980 | 34.7 | 91.7% | 234 |
| AMPE 200L RG 6 | 22 | 980 | 41.0 | 92.2% | 251 |
| AMPE 225M PG 6 | 30 | 980 | 54.1 | 92.9% | 308 |
| AMPE 250M PG 6 | 37 | 985 | 65.7 | 93.3% | 383 |
| AMPE 280S G 6 | 45 | 985 | 78.6 | 93.7% | 501 |
| AMPE 280M G 6 | 55 | 985 | 94.6 | 94.1% | 573 |
AMPH electrical data – 460 V 60 Hz (NEMA Premium)
Efficiency to EISA, tested to CSA C390-10 and verified by UL; also IE3 to IEC 60034-30-1.
2 pole – 3600 rpm (22 models)
| Type | kW | HP | rpm | In @460 V (A) | η 100% | Weight (kg) |
|---|---|---|---|---|---|---|
| AMPH 80Z AA 2 | 0.75 | 1 | 3525 | 1.5 | 77.0% | 9.5 |
| AMPH 80Z BA 2 | 1.1 | 1.5 | 3490 | 2.0 | 84.0% | 11.1 |
| AMPH 80Z CA 2* | 1.5 | 2 | 3460 | 2.8 | 85.5% | 13.5 |
| AMPH 90S AA 2 | 1.5 | 2 | 3515 | 2.8 | 85.5% | 16.4 |
| AMPH 90L BA 2 | 2.2 | 3 | 3480 | 3.8 | 86.5% | 18.3 |
| AMPH 90L DA 2* | 3 | 4 | 3510 | 5.3 | 88.5% | 18.0 |
| AMPH 100L AA 2 | 3 | 4 | 3515 | 4.9 | 88.5% | 23.6 |
| AMPH 100L BA 2* | 3.7 | 5 | 3540 | 7.0 | 88.5% | 26.5 |
| AMPH 100L CA 2* | 4 | 5.5 | 3530 | 7.4 | 88.5% | 26.5 |
| AMPH 112M AA 2 | 3.7 | 5 | 3535 | 5.8 | 88.5% | 27.4 |
| AMPH 112M BA 2 | 4 | 5.5 | 3520 | 6.2 | 88.5% | 27.4 |
| AMPH 112M CA 2* | 5.5 | 7.5 | 3530 | 8.9 | 89.5% | 35.5 |
| AMPH 112M DA 2* | 7.5 | 10 | 3530 | 11.9 | 90.2% | 36.5 |
| AMPH 132S ZA 2 | 5.5 | 7.5 | 3540 | 8.8 | 89.5% | 42.0 |
| AMPH 132S TA 2 | 7.5 | 10 | 3540 | 12.0 | 90.2% | 48.0 |
| AMPH 132M TA 2 | 9.2 | 12.4 | 3545 | 14.5 | 90.2% | 50.0 |
| AMPH 132M RA 2* | 11 | 15 | 3535 | 17.7 | 91.0% | 60.1 |
| AMPH 132M ZA 2* | 15 | 20 | 3530 | 23.5 | 91.0% | 68.0 |
| AMPH 160M YA 2 | 11 | 15 | 3550 | 17.0 | 91.0% | 90.0 |
| AMPH 160M ZA 2 | 15 | 20 | 3555 | 23.4 | 91.0% | 92.0 |
| AMPH 160L ZA 2 | 18.5 | 25 | 3555 | 31.0 | 91.7% | 108 |
| AMPH 160L TA 2* | 22 | 30 | 3540 | 35.8 | 91.7% | 108 |
4 pole – 1800 rpm (16 models)
| Type | kW | HP | rpm | In @460 V (A) | η 100% | Weight (kg) |
|---|---|---|---|---|---|---|
| AMPH 80Z AA 4 | 0.75 | 1 | 1740 | 1.45 | 85.5% | 11.0 |
| AMPH 90S AA 4 | 1.1 | 1.5 | 1745 | 2.2 | 86.5% | 18.8 |
| AMPH 90L BA 4 | 1.5 | 2 | 1735 | 2.9 | 86.5% | 18.8 |
| AMPH 90L CA 4 | 1.8 | 2.4 | 1730 | 3.8 | 86.5% | 18.8 |
| AMPH 100L AA 4 | 2.2 | 3 | 1760 | 3.8 | 89.5% | 25.0 |
| AMPH 100L BA 4 | 3 | 4 | 1765 | 5.3 | 89.5% | 28.0 |
| AMPH 112M AA 4 | 3.7 | 5 | 1765 | 6.5 | 89.5% | 35.7 |
| AMPH 112M BA 4 | 4 | 5.5 | 1760 | 6.9 | 89.5% | 35.7 |
| AMPH 132S AA 4 | 5.5 | 7.5 | 1770 | 9.0 | 91.7% | 49.0 |
| AMPH 132M BA 4 | 7.5 | 10 | 1765 | 12.5 | 91.7% | 54.0 |
| AMPH 132M CA 4 | 9.2 | 12.4 | 1765 | 15.2 | 91.7% | 62.0 |
| AMPH 132M DA 4* | 11 | 15 | 1770 | 18.5 | 92.4% | 71.0 |
| AMPH 160M AA 4 | 11 | 15 | 1770 | 18.6 | 92.4% | 100 |
| AMPH 160L BA 4 | 15 | 20 | 1770 | 24.8 | 93.0% | 105 |
| AMPH 160L CA 4* | 18.5 | 25 | 1770 | 32.5 | 93.6% | 110 |
| AMPH 160L DA 4* | 22 | 30 | 1770 | 35.6 | 93.6% | 127 |
6 pole – 1200 rpm (11 models)
| Type | kW | HP | rpm | In @460 V (A) | η 100% | Weight (kg) |
|---|---|---|---|---|---|---|
| AMPH 90S AA 6 | 0.75 | 1 | 1155 | 2.05 | 82.5% | 18.1 |
| AMPH 100L AA 6* | 1.1 | 1.5 | 1175 | 2.5 | 87.5% | 28.0 |
| AMPH 112M AA 6 | 1.1 | 1.5 | 1180 | 2.5 | 87.5% | 34.2 |
| AMPH 112M BA 6 | 1.5 | 2 | 1180 | 3.5 | 88.5% | 36.5 |
| AMPH 112M CA 6 | 1.8 | 2.4 | 1170 | 3.9 | 88.5% | 36.5 |
| AMPH 132S AA 6 | 2.2 | 3 | 1175 | 4.7 | 89.5% | 46 |
| AMPH 132S BA 6 | 3 | 4 | 1175 | 6.4 | 89.5% | 48 |
| AMPH 132M CA 6 | 4 | 5.5 | 1175 | 7.9 | 89.5% | 50 |
| AMPH 160M AA 6 | 5.5 | 7.5 | 1180 | 9.8 | 91.0% | 84 |
| AMPH 160M BA 6 | 7.5 | 10 | 1180 | 13.6 | 91.0% | 105 |
| AMPH 160L CA 6 | 9.2 | 12.4 | 1175 | 16.4 | 91.0% | 115 |
For Gulf sites: heat, 60 Hz and Saudi IE3
- Saudi Arabia – SASO 2893: IE3 is mandatory for three-phase motors from 0.75 to 375 kW (380 / 400 V, 60 Hz). Choose IE3 or IE4.
- 60 Hz: three-phase single-speed motors are marked with a 50 Hz and a 60 Hz voltage range. On 60 Hz with proportionally higher voltage, speed rises by 1.2× and output by 1.15×. Windings for 380 / 400 V 60 Hz are available on request.
- Ambient above 40 °C: with class B temperature rise the rated output falls to about 95% at 45 °C, 90% at 50 °C, 85% at 55 °C and 80% at 60 °C. A winding utilised to class F needs no derating up to 55 °C – tell us your site temperature.
- Coastal and outdoor sites: special finish K1 for corrosive chemical and marine atmospheres, anti-condensation heaters and drain holes.
How to read a Lafert type designation
Example: AMPE 90L BA 4. Send us the full type from the nameplate and we identify the exact motor.
Construction and standards
| Feature | Standard design |
|---|---|
| Standards | IEC 60034, IEC 60072 dimensions, CE (LVD, EMC, RoHS) |
| Degree of protection | IP55 (higher on request) |
| Insulation | Class F, temperature rise class B (80 K) |
| Ambient / altitude | up to 40 °C, up to 1000 m |
| Frame material | Aluminium alloy 56 – 160 · cast iron 180 – 315 |
| Terminal box | On top (left or right possible), entries turnable 90° · removable feet on 71 – 160 |
| Mounting | IM B3, B5, B14, B35, V1 and others (IEC 60034-7) |
| Paint | RAL 9005 black · K1 finish for marine and chemical atmospheres |
| Approvals on request | UL, CSA, CQC, EAC, UKCA |
Bearings by frame size
| Frame | Poles | Bearings DE / NDE | Dimensions (mm) |
|---|---|---|---|
| 56 | 2 – 4 | 6201-2Z | 12 × 32 × 10 |
| 63 | 2 – 4 | 6202-2Z | 15 × 35 × 11 |
| 71 | 2 – 8 | 6203-2Z | 17 × 40 × 12 |
| 80 | 2 – 8 | 6204-2Z | 20 × 47 × 14 |
| 90 | 2 – 8 | 6205-2Z | 25 × 52 × 15 |
| 100 | 2 – 8 | 6206-2Z | 30 × 62 × 16 |
| 112 | 2 – 8 | 6306-2Z | 30 × 72 × 19 |
| 132 | 2 – 8 | 6208-2Z | 40 × 80 × 18 |
| 160 | 2 – 8 | 6309-2Z | 45 × 100 × 25 |
| 180 | 2 – 6 | 6311 C3 | 55 × 120 × 29 |
| 200 | 2 – 6 | 6312 C3 | 60 × 130 × 31 |
| 225 | 2 – 6 | 6313 C3 | 65 × 140 × 33 |
| 250 | 2 – 6 | 6314 C3 | 70 × 150 × 35 |
| 280 | 2 / 4 – 6 | 6314 C3 / 6317 C3 | 80 × 170 × 39 / 85 × 180 × 41 |
| 315 | 2 / 4 – 6 | 6317 C3 / NU319 – 6319 C3 | 85 × 180 × 41 / 95 × 200 × 45 |
Bearings are lubricated for life up to frame 160; from frame 180 the motors have regreasing nipples. Roller bearings and oversized bearings are available as options.
Options
- Thermal protection: PTC thermistors, bimetal N/C or N/O, PT100
- Anti-condensation heaters (110 or 230 V)
- Encoder (200 – 2048 ppr) and forced ventilation (MFV)
- Protective cowl for vertical shaft-down mounting
- Smaller and oversized B5 / B14 flanges, cast iron endshields
- Oversized and roller bearings, regreasing device
- Double shaft and special shaft extensions
- Vibration grade B, special balancing
- NEMA C-face (frames 71 – 160)
- Windings for special voltages and 60 Hz
Frequently asked questions
Are Lafert AMPE motors suitable for Saudi Arabia?
Yes. AMPE motors are IE3, the level required by SASO 2893 for three-phase motors from 0.75 to 375 kW. For Saudi 380 / 400 V 60 Hz networks we confirm the winding and nameplate data with the quotation.
What is the difference between AMPE and AMPH?
AMPE is the IE3 range rated for 400 V 50 Hz. AMPH is rated for 460 V 60 Hz and meets NEMA Premium efficiency (EISA), verified by UL.
What does the * on some models mean?
It marks higher-output (progressive) motors: more kW in the same frame size, useful when space is limited.
Can a 50 Hz IE3 motor run on 60 Hz?
Yes, if the voltage rises in proportion (for example 400 V 50 Hz to 460 V 60 Hz); speed then increases by 1.2 and output by 1.15. At unchanged voltage the output cannot be increased.
What do you need to quote a replacement?
The full type from the nameplate (for example AMPE 132M BA 4), mounting arrangement (B3, B5, B14…), voltage, frequency and quantity.
Need Lafert IE3 motors?
Send us the type, kW, poles and mounting – or a nameplate photo – and we reply with a quotation.
Data from the Lafert catalogue 10-260/24 at rated voltage. Technical data are subject to change by the manufacturer; final values are confirmed with the quotation. Lafert is a trademark of Lafert S.p.A.